Kormax workshop micrometers are engineered for absolute metrological inspection of turned, milled, and ground workpieces with an accuracy of 0.01 mm, eliminating the risk of scrapped parts at quality control. Utilizing a precision-ground micrometer spindle with a 0.5 mm pitch paired with tungsten carbide measuring faces, turners and machinists can reliably verify interference and sliding fits without dimensional distortion caused by swarf or coolant films.
- Reading Resolution: 0.01 mm on a satin-chrome finished thimble and sleeve.
- External Measurement Ranges: 0–25 mm, 25–50 mm, 50–75 mm, and 75–100 mm.
- Internal Measurement Ranges: 5–30 mm, 25–50 mm, 50–75 mm, and 75–100 mm.
- Contact Anvils: Tungsten carbide (HM / TCT) tipped faces with hardness exceeding 65 HRC.
- Constant Measuring Force: Integrated ratchet stop clutch delivering a consistent 5–10 N force.
- Set Inclusions: Setting standards (for models over 25 mm), adjustment spanner wrench, protective fitted case.
When to Choose an External Outside Micrometer vs. an Internal Caliper-Type Inside Micrometer?
The Kormax MT1802 external frame micrometer is the baseline inspection tool for gauging outside shaft diameters, bearing journals, plate thickness, and precision-machined flat stock. The rigid, drop-forged steel bow frame guarantees zero structural flex under spindle torque against the workpiece, safeguarding the machine operator against negative measurement errors on tight IT6–IT8 tolerance fits.
The Kormax MT1801 internal caliper-type inside micrometer is built for precise gauging of pipe IDs, machine housing bores, and deep keyway slot widths. Cylindrically radiused measuring jaws ensure positive, self-aligning seating across the bore axis, minimizing misalignment errors when inspecting sleeve bushings and rolling-element bearing fits.
Why Does the Ratchet Stop Mechanism Dictate Repeatable Measurement?
The micrometer's ratchet stop (friction thimble) standardizes spindle clamping force on the measured component within a fixed 5 to 10 N window, taking machinist hand feel completely out of the equation. This ratchet mechanism prevents elastic deformation of the bow frame as well as crushing of thin-walled turned sleeves, ensuring identical dimensional readouts across repetitive batch-run inspections.
Carbide-tipped measuring faces fitted to both the anvil and spindle guard the instrument against micro-abrasion wear caused by repeated friction against rough-machined steel. Sintered carbide's extreme wear resistance against industrial coolants and cutting emulsions ensures the flat-and-parallel contact faces hold their DIN 863 accuracy class across thousands of shop-floor measuring cycles.
Kormax Expert Tip: How to Eliminate Thermal Expansion Errors and Zero Your Micrometer Correctly
Kormax tooling specialists advise against gripping the bare steel bow frame with an uninsulated hand when verifying fits under 0.02 mm tolerance. Body heat around 36°C transferring into the steel frame induces thermal expansion, causing measurement drift on the order of 0.003–0.005 mm. Always hold the micrometer by its thermal insulation grip plates or mount the instrument in a rigid bench micrometer stand at the standard reference temperature of 20°C.
Prior to starting an inspection run, clean the contact faces by lightly clamping a clean slip of paper between the spindle and anvil and drawing it through, then verify zero against the included setting standard. If the thimble zero mark does not align dead-on with the sleeve index line, lock the spindle clamp and adjust the sleeve position using the supplied hook spanner wrench by rotating the graduated sleeve along the tool axis.
Technical Specifications: Workshop Micrometers
| Model Code |
Tool Type |
Measuring Range |
Graduation |
Measuring Faces |
Included Accessories |
| MT1802-11 |
Outside (Frame Type) |
0 – 25 mm |
0.01 mm |
Tungsten Carbide (HM) |
Spanner wrench, fitted case |
| MT1802-21 |
Outside (Frame Type) |
25 – 50 mm |
0.01 mm |
Tungsten Carbide (HM) |
25 mm standard, wrench, fitted case |
| MT1802-31 |
Outside (Frame Type) |
50 – 75 mm |
0.01 mm |
Tungsten Carbide (HM) |
50 mm standard, wrench, fitted case |
| MT1802-41 |
Outside (Frame Type) |
75 – 100 mm |
0.01 mm |
Tungsten Carbide (HM) |
75 mm standard, wrench, fitted case |
| MT1801-11 |
Inside (Caliper Type) |
5 – 30 mm |
0.01 mm |
Hardened Alloy Steel |
Setting ring, wrench, fitted case |
| MT1801-21 |
Inside (Caliper Type) |
25 – 50 mm |
0.01 mm |
Hardened Alloy Steel |
Setting ring, wrench, fitted case |
| MT1801-31 |
Inside (Caliper Type) |
50 – 75 mm |
0.01 mm |
Hardened Alloy Steel |
Spanner wrench, fitted case |
| MT1801-41 |
Inside (Caliper Type) |
75 – 100 mm |
0.01 mm |
Hardened Alloy Steel |
Spanner wrench, fitted case |
How to Outfit a Quality Control Station on the Shop Floor?
Select Kormax micrometers across the appropriate measuring spans to safeguard your production line against costly out-of-spec scrap and speed up in-process inspection right at the machine tool. For rough envelope checks prior to grinding, outfit your bench with vernier or digital workshop calipers, and deploy dial indicators on magnetic bases for verifying shaft radial runout and spindle alignment.